Source Code
|
These source-code files are part of a reconstructed copy of Luminary 97, the
original release of the Apollo 11 Lunar Module (LM) Apollo Guidance Computer
(AGC) software.
The reconstruction began with source code of Luminary 99 revision 1 previously transcribed from a digitized copy of that program. The code was then updated by undoing changes described in original Luminary memos 83 and 85, using asterisks indicating changed lines in the listing as a guide. The reconstruction was verified by matching memory-bank checksums to those listed in drawing 2021152D. Note that page numbers in the reconstructed code match those on the Luminary 099 revision 001 printout, although the added code would likely have changed page numbers for a real Luminary 97 listing. Comments from the original source code are prefixed with a single '#' symbol, whereas comments added later are prefixed by "##" or "###". Report any errors noted by creating an issue report at the Virtual AGC project's GitHub repository. |
009592,000002: ## Copyright: Public domain.
009593,000003: ## Filename: RESTART_TABLES.agc
009594,000004: ## Purpose: A section of Luminary revision 97.
009595,000005: ## It is part of the reconstructed source code for the
009596,000006: ## original release of the flight software for the Lunar
009597,000007: ## Module's (LM) Apollo Guidance Computer (AGC) for Apollo 11.
009598,000008: ## The code has been recreated from a copy of Luminary 99
009599,000009: ## revision 001, using asterisks indicating changed lines in
009600,000010: ## the listing and Luminary Memos #83 and #85, which list
009601,000011: ## changes between Luminary 97 and 98, and 98 and 99. The
009602,000012: ## code has been adapted such that the resulting bugger words
009603,000013: ## exactly match those specified for Luminary 97 in NASA drawing
009604,000014: ## 2021152D, which gives relatively high confidence that the
009605,000015: ## reconstruction is correct.
009606,000016: ## Reference: pp. 238-243
009607,000017: ## Assembler: yaYUL
009608,000018: ## Contact: Ron Burkey <info@sandroid.org>.
009609,000019: ## Website: www.ibiblio.org/apollo/index.html
009610,000020: ## Mod history: 2019-07-28 MAS Created from Luminary 99.
009611,000021:
|
Page 238 |
009613,000023: # RESTART TABLES
009614,000024: # ------------------
009615,000025:
009616,000026: # THERE ARE TWO FORMS OF RESTART TABLES FOR EACH GROUP. THEY ARE KNOWN AS THE EVEN RESTART TABLES AND THE ODD
009617,000027: # RESTART TABLES. THE ODD TABLES HAVE ONLY ONE ENTRY OF THREE LOCATIONS WHILE THE EVEN TABLES HAVE TWO ENTRIES
009618,000028: # EACH USING THREE LOCATIONS. THE INFORMATION AS TO WHETHER IT IS A JOB, WAITLIST, OR A LONGCALL IS GIVEN BY THE
009619,000029: # WAY THINGS ARE PUT IN TO THE TABLES.
009620,000030:
009621,000031: # A JOB HAS ITS PRIORITY STORED IN PRDTTAB OF THE CORRECT PHASE SPOT - A POSITIVE PRIORITY INDICATES A
009622,000032: # FINDVAC JOB, A NEGATIVE PRIORITY A NOVAC. THE 2CADR OF THE JOB IS STORED IN THE CADRTAB.
009623,000033: # FOR EXAMPLE,
009624,000034:
009625,000035: # 5.7SPOT OCT 23000
009626,000036: # 2CADR SOMEJOB
009627,000037:
009628,000038: # A RESTART OF GROUP 5 WITH PHASE SEVEN WOULD THEN CAUSE SOMEJOB TO BE RESTARTED AS A FINDVAC WITH PRIORITY 23.
009629,000039:
009630,000040: # 5.5SPOT OCT -23000
009631,000041: # 2CADR ANYJOB
009632,000042:
009633,000043: # HERE A RESTART OF GROUP 5 WITH PHASE 7 WOULD CAUSE ANYJOB TO BE RESTARTED AS A NOVAC WITH PRIORITY 23.
009634,000044: # A LONGCALL HAS ITS GENADR OF ITS 2CADR STORED NEGATIVELY AND ITS BBCON STORED POSITIVELY. IN ITS PRDTTAB IS
009635,000045: # PLACED THE LOCATION OF A DP REGISTER THAT CONTAINS THE DELTA TIME THAT LONGCALL HAD BEEN ORIGINALLY STARTED
009636,000046: # WITH. EXAMPLE,
009637,000047:
009638,000048: # 3.6SPOT GENADR DELTAT
009639,000049: # -GENADR LONGTASK
009640,000050: # BBCON LONGTASK
009641,000051: # OCT 31000
009642,000052: # 2CADR JOBAGAIN
009643,000053:
009644,000054: # THIS WOULD START UP LONGTASK AT THE APPROPRIATE TIME, OR IMMEDIATELY IF THE TIME HAD ALREADY PASSED. IT SHOULD
009645,000055: # BE NOTED THAT IF DELTAT IS IN A SWITCHED E BANK, THIS INFORMATOIN SHOULD BE IN THE BBCON OF THE 2CADR OF THE
009646,000056: # TASK. FROM ABOVE, WE SEE THAT THE SECOND PART OF THIS PHASE WOULD BE STARTED AS A JOB WITH A PRIORITY OF 31.
009647,000057:
009648,000058: # WAITLIST CALLS ARE IDENTIFIED BY THE FACT THAT THEIR 2CADR IS STORED NEGATIVELY. IF PRDTTAB OF THE PHASE SPOT
009649,000059: # IS POSITIVE, THEN IT CONTAINS THE DELTA TIME, IF PRDTTAB IS NEGATIVE THEN IT IS THE -GENADR OF AN ERASABLE
009650,000060: # LOCATION CONTAINING THE DELTA TIME, THAT IS, THE TIME IS STORED INDIRECTLY. IT SHOULD BE NOTED AS ABOVE, THAT
009651,000061: # IF THE TIME IS STORED INDIRECTLY, THE BBCON MUST CONTAIN THE NECESSARY E BANK INFORMATION IF APPLICABLE. WITH
009652,000062: # WAITLIST WE HAVE ONE FURTHER OPTION, IF -0 IS STORED IN PRDTTAB, IT WILL CAUSE AN IMMEDIATE RESTART OF THE
009653,000063: # TASK. EXAMPLES,
009654,000064:
009655,000065: # OCT 77777 THIS WILL CAUSE AN IMMEDIATE RESTART
009656,000066: # -2CADR ATASK OF THE TASK :ATASK:
009657,000067: #
009658,000068: # DEC 200 IF THE TIME OF THE 2 SECONDS SINCE DUMMY
009659,000069: # -2CADR DUMMY WAS PUT ON WAITLIST IS UP, IT WILL BEGIN
009660,000070: # IN 10 MS, OTHERWISE IT WILL BEGIN WHEN
009661,000071: # IT NORMALLY WOULD HAVE BEGUN.
|
Page 239 |
009663,000073: # -GENADR DTIME WHERE DTIME CONTAINS THE DELTA TIME
009664,000074: # -2CADR TASKTASK OTHERWISE THIS IS AS ABOVE
009665,000075:
009666,000076: # ***** NOW THE TABLES THEMSELVES *****
009667,000077:
009668,000078: 01,2002 BANK 01
009669,000079: 01,2000 SETLOC RESTART
009670,000080: 01,2000 BANK
009671,000081:
009672,000082: 01,2002 PRDTTAB EQUALS 12000 # USED TO FIND THE PRIORITY OR DELTATIME
009673,000083: 01,2002 CADRTAB EQUALS 12001 # THIS AND THE NEXT RELATIVE LOC CONTAIN
009674,000084: # RESTART 2CADR
009675,000085:
009676,000086: 01,2002 COUNT* $$/RSTAB # TABLES IN BANK 1.
009677,000087: 01,2002 00010 SIZETAB TC 1.2SPOT -12006
009678,000088: 01,2003 00020 TC 1.3SPOT -12004
009679,000089: 01,2004 00010 TC 2.2SPOT -12006
009680,000090: 01,2005 00023 TC 2.3SPOT -12004
009681,000091: 01,2006 00010 TC 3.2SPOT -12006
009682,000092: 01,2007 00053 TC 3.3SPOT -12004
009683,000093: 01,2010 00057 TC 4.2SPOT -12006
009684,000094: 01,2011 00067 TC 4.3SPOT -12004
009685,000095: 01,2012 00142 TC 5.2SPOT -12006
009686,000096: 01,2013 00160 TC 5.3SPOT -12004
009687,000097: 01,2014 00010 TC 6.2SPOT -12006
009688,000098: 01,2015 00171 TC 6.3SPOT -12004
009689,000099: 01,2016 21000 1.2SPOT OCT 21000 # A DUMMY EXAMPLE TO BE REPLACED AS SOON
009690,000100: 01,2017 0074 EBANK= STATE
009691,000101: 01,2017 05155 04060 2CADR ENDOFJOB # AS THERE IS A LEGITIMATE 1.2SPOT
009692,000102:
009693,000103: 01,2021 00144 DEC 100 B-14
009694,000104: 01,2022 0074 EBANK= STATE
009695,000105: 01,2022 05261 04060 2CADR TASKOVER
009696,000106:
009697,000107: # ANY MORE GROUP 1.EVEN RESTART VALUES SHOULD GO HERE
009698,000108:
009699,000109: 01,2024 76300 1.3SPOT -GENADR SAVET-30
009700,000110: 01,2025 E7,1515 EBANK= DVCNTR
009701,000111: 01,2025 75431 03710 -2CADR ULLGTASK
009702,000112:
009703,000113: # ANY MORE GROUP 1.ODD RESTART VALUES SHOULD GO HERE
009704,000114:
009705,000115: 01,2027 01,2016 2.2SPOT EQUALS 1.2SPOT
009706,000116:
009707,000117: # ANY MORE GROUP 2.EVEN RESTART VALUES SHOULD GO HERE
009708,000118:
009709,000119: 01,2027 02630 2.3SPOT GENADR 600SECS
009710,000120:
009711,000121: 01,2030 75173 -GENADR STATEINT
009712,000122: 01,2031 E3,1554 EBANK= RRECTCSM
009713,000123: 01,2031 26063 BBCON STATEINT
009714,000124:
|
Page 240 |
009716,000126: 01,2032 05000 2.5SPOT OCT 05000
009717,000127: 01,2033 E3,1554 EBANK= RRECTCSM
009718,000128: 01,2033 02613 26063 2CADR STATINT1
009719,000129:
009720,000130: 01,2035 02734 2.7SPOT DEC 1500 B-14
009721,000131: 01,2036 E7,1456 EBANK= LOSCOUNT
009722,000132: 01,2036 75533 27710 -2CADR P20LEMC1
009723,000133:
009724,000134: 01,2040 14000 2.11SPOT OCT 14000
009725,000135: 01,2041 E7,1762 EBANK= P21TIME
009726,000136: 01,2041 02416 50067 2CADR P25LEM1
009727,000137:
009728,000138: 01,2043 10000 2.13SPOT OCT 10000
009729,000139: 01,2044 E7,1456 EBANK= LOSCOUNT
009730,000140: 01,2044 02217 54067 2CADR RELINUS
009731,000141:
009732,000142: 01,2046 26000 2.15SPOT OCT 26000
009733,000143: 01,2047 E7,1456 EBANK= LOSCOUNT
009734,000144: 01,2047 02653 50067 2CADR R22RSTRT
009735,000145:
009736,000146: 01,2051 77777 2.17SPOT OCT 77777
009737,000147: 01,2052 E7,1700 EBANK= VGPREV
009738,000148: 01,2052 75440 03710 -2CADR REDO2.17
009739,000149:
009740,000150: 01,2054 00031 2.21SPOT DEC 25 B-14
009741,000151: 01,2055 E7,1515 EBANK= DVCNTR
009742,000152: 01,2055 75771 35710 -2CADR R10,R11
009743,000153:
009744,000154: # ANY MORE GROUP 2.ODD RESTART VALUES SHOULD GO HERE.
009745,000155:
009746,000156: 01,2057 01,2016 3.2SPOT EQUALS 1.2SPOT
009747,000157:
009748,000158: # ANY MORE GROUP 3.EVEN RESTART VALUES SHOULD GO HERE
009749,000159:
009750,000160: 01,2057 76355 3.3SPOT -GENADR ZOOMTIME
009751,000161: 01,2060 E7,1515 EBANK= DVCNTR
009752,000162: 01,2060 75755 41710 -2CADR ZOOM
009753,000163:
009754,000164: 01,2062 20000 3.5SPOT OCT 20000
009755,000165: 01,2063 E7,1453 EBANK= TTOGO
009756,000166: 01,2063 02540 56067 2CADR S40.13
009757,000167:
009758,000168: # ANY MORE GROUP 3.ODD RESTART VALUES SHOULD GO HERE
009759,000169:
009760,000170: 01,2065 04704 4.2SPOT DEC 2500 B-14
009761,000171: 01,2066 E7,1453 EBANK= TTOGO
009762,000172:
009763,000173: 01,2066 75425 03710 -2CADR TIG-5
009764,000174:
009765,000175: 01,2070 77777 OCT 77777
009766,000176: 01,2071 E7,1453 EBANK= TTOGO
|
Page 241 |
009768,000178: 01,2071 75435 03710 -2CADR REDO4.2
009769,000179:
009770,000180: # ANY MORE GROUP 4.EVEN RESTART VALUES SHOULD GO HERE
009771,000181:
009772,000182: 01,2073 25000 4.3SPOT OCT 25000
009773,000183: 01,2074 E7,1515 EBANK= DVCNTR
009774,000184: 01,2074 03540 64067 2CADR GOABORT
009775,000185:
009776,000186: 01,2076 00062 4.5SPOT DEC 50 B-14
009777,000187: 01,2077 E7,1453 EBANK= TTOGO
009778,000188: 01,2077 75215 03710 -2CADR ULLAGOFF
009779,000189:
009780,000190: 01,2101 00764 4.7SPOT DEC 500 B-14
009781,000191: 01,2102 E7,1515 EBANK= DVCNTR
009782,000192: 01,2102 75374 03710 -2CADR TIG-0
009783,000193:
009784,000194: 01,2104 76260 4.11SPOT -GENADR TGO +1
009785,000195: 01,2105 E7,1515 EBANK= DVCNTR
009786,000196: 01,2105 74235 03710 -2CADR ENGOFTSK
009787,000197:
009788,000198: 01,2107 12000 4.13SPOT OCT 12000
009789,000199: 01,2110 E7,1462 EBANK= TRKMKCNT
009790,000200: 01,2110 03223 74067 2CADR POSTBURN
009791,000201:
009792,000202: 01,2112 00764 4.15SPOT DEC 500 B-14
009793,000203: 01,2113 E7,1453 EBANK= TTOGO
009794,000204: 01,2113 75501 03710 -2CADR TIG-30
009795,000205:
009796,000206: 01,2115 77777 4.17SPOT OCT 77777
009797,000207: 01,2116 E7,1515 EBANK= DVCNTR
009798,000208: 01,2116 75425 03710 -2CADR TIG-5
009799,000209:
009800,000210: 01,2120 13000 4.21SPOT OCT 13000
009801,000211: 01,2121 E5,1730 EBANK= STAR
009802,000212: 01,2121 03020 30065 2CADR R51.1 +1
009803,000213:
009804,000214: 01,2123 77777 4.23SPOT OCT 77777
009805,000215: 01,2124 E7,1515 EBANK= DVCNTR
009806,000216: 01,2124 75351 03710 -2CADR IGNITION
009807,000217:
009808,000218: 01,2126 01477 4.25SPOT GENADR SAVET-30
009809,000219: 01,2127 75537 -GENADR TIG-35
009810,000220: 01,2130 E7,1477 EBANK= SAVET-30
009811,000221: 01,2130 74067 BBCON TIG-35
009812,000222:
009813,000223:
009814,000224: 01,2131 52777 4.27SPOT OCT 52777
009815,000225: 01,2132 E7,1515 EBANK= DVCNTR
009816,000226: 01,2132 02073 42067 2CADR P70A
|
Page 242 |
009818,000228: 01,2134 52777 4.31SPOT OCT 52777
009819,000229: 01,2135 E7,1515 EBANK= DVCNTR
009820,000230: 01,2135 02076 42067 2CADR P71A
009821,000231:
009822,000232: 01,2137 46777 4.33SPOT OCT 46777
009823,000233: 01,2140 E7,1515 EBANK= DVCNTR
009824,000234: 01,2140 02024 10067 2CADR GOPOOFIX
009825,000235:
009826,000236: 01,2142 46777 4.35SPOT OCT 46777
009827,000237: 01,2143 E7,1515 EBANK= DVCNTR
009828,000238: 01,2143 05665 04067 2CADR GOPOODOO
009829,000239:
009830,000240: 01,2145 52777 4.37SPOT OCT 52777
009831,000241: 01,2146 E7,1455 EBANK= WHICH
009832,000242: 01,2146 02571 74067 2CADR COMFAIL
009833,000243:
009834,000244: # ANY MORE 4.ODD RESTART VALUES SHOULD GO HERE.
009835,000245: 01,2150 22000 5.2SPOT OCT 22000
009836,000246: 01,2151 E7,1515 EBANK= DVCNTR
009837,000247: 01,2151 02461 46067 2CADR NORMLIZE
009838,000248:
009839,000249: 01,2153 00310 DEC 200 B-14
009840,000250: 01,2154 E7,1515 EBANK= DVCNTR
009841,000251: 01,2154 74163 01710 -2CADR REREADAC
009842,000252:
009843,000253: 01,2156 00310 5.4SPOT DEC 200 B-14
009844,000254: 01,2157 E7,1515 EBANK= DVCNTR
009845,000255: 01,2157 74163 01710 -2CADR REREADAC
009846,000256:
009847,000257: 01,2161 20000 OCT 20000
009848,000258: 01,2162 E7,1515 EBANK= DVCNTR
009849,000259: 01,2162 02206 66067 2CADR SERVICER
009850,000260:
009851,000261: # ANY MORE GROUP 5.EVEN RESTART VALUES SHOULD GO HERE
009852,000262:
009853,000263: 01,2164 00310 5.3SPOT DEC 200 B-14
009854,000264: 01,2165 E7,1515 EBANK= DVCNTR
009855,000265: 01,2165 74163 01710 -2CADR REREADAC
009856,000266:
009857,000267: 01,2167 77777 5.5SPOT OCT 77777
009858,000268: 01,2170 E7,1515 EBANK= DVCNTR
009859,000269: 01,2170 74324 01710 -2CADR REDO5.5
009860,000270:
009861,000271: 01,2172 77777 5.7SPOT OCT 77777
009862,000272: 01,2173 E7,1515 EBANK= DVCNTR
|
Page 243 |
009864,000274: 01,2173 74361 01710 -2CADR BIBIBIAS
009865,000275:
009866,000276: # ANY MORE GROUP 5.ODD RESTART VALUES SHOULD GO HERE
009867,000277:
009868,000278: 01,2175 01,2016 6.2SPOT EQUALS 1.2SPOT
009869,000279: 01,2175 00144 6.3SPOT DEC 100 B-14
009870,000280: 01,2176 E7,1441 EBANK= TIG
009871,000281: 01,2176 75060 03710 -2CADR CLOKTASK
009872,000282:
009873,000283: 01,2200 30000 6.5SPOT OCT 30000 # PROTECT INCREMENTING OF TIME2,TIME1 BY
009874,000284: 01,2201 E3,1706 EBANK= TEPHEM # P27(UPDATE PROGRAM) VIA V70 OR V73.
009875,000285: 01,2201 03601 10063 2CADR TIMEDIDR
009876,000286:
009877,000287: 01,2203 17000 6.7SPOT OCT 17000
009878,000288: 01,2204 E7,1700 EBANK= VGPREV
009879,000289: 01,2204 03350 74067 2CADR REDO6.7
009880,000290:
009881,000291:
End of include-file RESTART_TABLES.agc. Parent file is MAIN.agc